Guardian Technologies Ademco VISTA-40 User Manual

Page 94

Advertising
background image

Р 94 Р

KEYPAD FUNCTIONS

General Information

The keypad allows the user to arm and disarm the system, and perform other
system functions, such as bypassing zones, view messages from the central
station and display zone descriptors. Zone and system conditions (alarm, trouble,
bypass) are displayed in the Display Window.
When an alarm occurs, keypad sounding and external sounding will occur, and
the zone(s) in alarm will be displayed on the keypad. Pressing any key will silence
the keypad sounder for 10 seconds. Disarming the system will silence both
keypad and external sounders. When the system is disarmed, any zones that
were in an alarm condition during the armed period will be displayed (memory of
alarm). To clear this display, simply repeat the disarm sequence (enter the security
code and press the OFF key).
The keypads also feature chime annunciation, and 3 panic key pairs (for silent,
audible, fire or personal emergency alarms) which can notify the central station of
an alarm condition, if that service is connected.
NOTE: Throughout this manual, the term "alpha keypad" refers equally to the
6139 alpha keypad or 6139AV voice/alpha keypad.

Phone Module

Refer to the separate instructions supplied with the Phone Module for
information concerning its operating procedures.
Important: The Phone Module cannot be used to add user codes in this
system. User codes must be added by using an alpha keypad only.

Arming Functions

Note that if QUICK ARM is
enabled (field *29), the [#]
key can be pressed instead
of entering the security
code, for any of the arming
procedures (Away, Stay,
Instant, Maximum, etc.).

The following is a brief list of system commands. For detailed information
concerning system functions, refer to the User's Manual.
Disarmed, Not Ready Before arming, the system must be in the READY

condition (all zones must be intact). If the "NOT
READY" message appears, press the READY [*] key
to display faulted zones.

Arming Away

Enter code + AWAY [2].

Arming Stay

Enter code + STAY [3].

Arming Instant

Enter code + INSTANT [7].

Arming Maximum

Enter code + MAXIMUM [4].

Global Arming

If enabled for the user, the keypad will display the
following:

ARM ALL ?
0 = NO , 1 = YES

If NO, the keypad prompts for arming each partition
individually. If YES, the system attempts to arm all partitions
allowed by this user. If there are any faults (open doors,
windows, etc.) the keypad will display them. See notes below.
These faults must be corrected or the zone bypassed before
arming will occur. When faults are corrected, repeat the arming
procedure.

Global Arming Notes:

1.

When using the Global Arm feature, if there are faults in
any of the selected partitions, the system will enter a
summary mode in which the faulted zones of all of the
selected partitions will be displayed. These faults must be
corrected or bypassed (code + BYPASS + [#] will attempt
to bypass the faults in all of the selected partitions). This
summary mode will end in approx. 120 seconds if no keys
are pressed.

2.

If, when disarming the system using a Global Disarm, any
of the selected partitions has a condition which would
cause the keypad to beep (such as alarm memory or a
trouble condition), the system will cause the keypad to
beep and will enter a summary mode in which the alarm
memory or trouble conditions of all of the selected
partitions will be displayed. This mode will continue until
either approx. 120 seconds elapses or a second disarm
occurs which clears the beeping condition.

3.

Global arming cannot be performed from a wireless keypad
or a non-alpha display keypad.

Disarming

Enter code + OFF [1].

Advertising
This manual is related to the following products: