Guardian Technologies Ademco VISTA-40 User Manual

Page 118

Advertising
background image

Р 4 Р

At any time during this step, you may press the [

] key on the keypad or the

upper left-hand button of the program tool if you are satisfied with the serial
and loop number combination that has been enrolled, regardless of whether
or not the enrolled input has been "confirmed."

If the incorrect device has been enrolled, press the # key on the keypad or
upper right-hand button on the program tool to delete the serial number and
return to the "LEARN S/N" prompt. A single long beep will be heard from the
keypad to verify pressing of the upper right-hand button. Then, press "1"
(Yes) or press the upper left-hand button of the program tool (a single short
beep will verify the system is ready for enrolling) and re-activate the proper
device loop input.

10 ZT P RC IN:L
s 03 1 00 RF:1

14. The summary screen for the zone will appear. Note that an "s" indicates

that a serial number has, in fact, been enrolled. Press [

] to accept the

zone information.

If you want to delete the serial number, press [#]. This will bring you back
to step 8. Press [

] to change input type, loop number, and serial

number.

When you have finished programming all zones, test each using the system's
TEST mode. Do not use the Transmitter ID Sniffer mode for this, as it will only
check for transmission of one zone on a particular transmitter, NOT the zones
assigned to each additional loop, and will not verify polling loop type zones.

ENROLLING THROUGH SEQUENTIAL MODE (#93)

(Use this mode only after all other zone information has been programmed, including
transmitter loop numbers).

To enroll devices sequentially,

after all other zone information has been

programmed, do the following:

1. Enter Programming mode [Installer Code] + 8 + 0 + 0 on an alpha

keypad. Enter Sequential mode by pressing #93. Press 0 repeatedly
until the "SEQUENTIAL LEARN" prompt is displayed. Enter "1" to enroll
a device's serial number. The following prompt will appear:

PROGRAM TOOL?
0 = NO, 1 = YES 0

2. If using a program tool, enter "1." If not using a tool, enter "0." If a tool

has already been programmed, this prompt will not appear. If either not
using a tool or one has already been programmed, skip to step 4.

00 INPUT S/N: L
Axxx-xxxx

3. If "1" is entered, the system will prompt for the unit’s serial number. Enter

the program tool’s serial number using one of the following methods:

a)

Enter the 7-digit serial number printed on the transmitter

or

b) Press any button on the transmitter. The keypad should beep three

times and display the serial number of the tool.

Advertising