1 system operation – Guardian Technologies Ademco VISTA-40 User Manual

Page 89

Advertising
background image

Р 89 Р

Section 1. SYSTEM OPERATION

SECURITY ACCESS CODES

General Information

The System allows up to a total of 70 security access codes to be assigned
(maximum of 69 in a given partition), each identified by a user ID number. In
addition, the Quick Arm feature can also be programmed, which enables the
[#] key to be pressed instead of entering the security code when arming the
system. The code must still be entered when disarming the system.

NOTE: Open/Close reporting of Quick Arm is enabled if User 2 is enabled for
Open/Close reporting. Quick Arm reports as User 0.

User Codes & Levels Of

Authority

L e v e l

Title

0

Installer

1

Master

2

Manager

3

Operator level A

4

Operator level B

5

Operator level C

6

Duress

Each user of the system can be assigned various levels of authority (tells system
what system functions that user is authorized to do), and can have different levels
of authority within each partition. Use the "View Capabilities" keypad function to
view the partitions and authority levels for which a particular user is authorized. In
highest to lowest ranking, these levels are described below.

Installer

¥ Programmed in field *00 (default = 4-1-4-0).

(Level 0)

Can be changed by installer.

User 1

¥ Can perform all system functions (arm, disarm, bypass,

etc.).

¥ Only code that allows entry to program mode.
¥ Installer code lockout if exit program mode via *98. This

prevents installer from re-accessing the program mode.
The only way to access Programming mode once this
feature is activated, is by powering down the system
and powering up again, and then pressing both the *
and # keys at the same time within 30 seconds of power
up.

¥ The installer must program at least one master

code. Master codes are the codes intended for use by
the primary users of the system.

¥ Can add, delete, or change master, manager, or

operator codes.

¥ Can select open/close reports for any user.
¥ Can perform normal system functions, but cannot

disarm if armed by a code other than Installer's code
(including Quick Arm).

¥ Enable open/close reporting for installer in field *39.

Master (Level 1)

¥ The Master Code is the code intended for use by the

primary users of the system when performing system
functions, and can be changed by the Master User.

¥ The master codes can be used to assign up to 68 lower

level codes, which can be used by other users of the
system who don't have a need to know the master
code.

¥ As shipped from the factory, there are no master or

manager codes pre-programmed. The installer must
program at least one master code during initial
installation.

¥ Master cannot assign anybody a level of 0 or 1.
¥ Can change his own code.
¥ Can add, delete, change manager or operator codes.

Each user's code can be individually eliminated or
changed at any time.

¥ Open/close reporting of added users are same as that

of the master or manager adding the new user.

¥ Can perform all system functions.

Advertising