Descriptors
¥ All programmed descriptors can be displayed (one at

a time) by pressing and holding the READY key for 5
seconds, then releasing the key. This serves as a
check for installers to be sure all descriptors are
entered properly.

Event Logging
¥ Event Logging feature keeps record of up to 100

events.

Access Control
¥ Provides user-activated access control command

which pulses a relay output for controlled opening of
access doors (e.g. lobby door).

#70 End User Relay Commands
¥ Allows end users to manually turn on/off relay/X-10

module outputs to control lights or other devices via
keypad or phone module.

Cabinet
¥ Large cabinet with removable door for easier

installations.

Programming Features

¥ Programming can be performed at the office prior to

installation, or on the job site directly from the
keypad.

¥ Can be downloaded from a remote location or at the

job site (using a PC/laptop with 4100SM Serial
Module) by using the AdemcoÕs V-Link¨
downloading software (Rev. 4 or higher) or AdemcoÕs

Compass

Windows downloading software.

¥ The Control is pre-programmed with a set of standard

values that is designed to meet the needs of many
installations. These values, however, can be
changed to suit the needs of any particular
installation.

¥ The Control can also be pre-programmed by the

installer with one of four standard communication
default programming values, thus further saving time
and effort.

Installer Code
¥ Installer code override feature. Installer code will

disarm system only if it was used to arm the system.

Prohibit Program Mode Entry
¥ If desired, entry to program mode via [

*

] + [#] within

30 seconds of power up can be disabled.

Alpha Descriptors
¥ All zones and partitions can be assigned

descriptions.

¥ The letter "s" or " 's " can be added to descriptors.

Relay Voice Descriptors
¥ Separate vocabulary for annunciating relay output

descriptors when using a phone module to activate
relays.

Custom Words
¥ Up to 20 custom words can be added to the built-in

vocabulary.

Voice Substitute Custom Words
¥ Provides a means of annunciating substitute words

for the phone module whenever a custom word is
used for alpha keypad displays.

Downloading
¥ Direct wire downloading can be done without a

modem, by using a PC or Laptop computer and
4100SM Module.

#93 Menu Mode
¥ Easy programming of zones using the user friendly

#93 Menu Mode.

Communication Features

Communication
¥ Ademco low speed, SESCOA/RADIONICS, Ademco

Express, Ademco High Speed, Ademco Contact ID.

Comm. Fields
¥ Easy programming for communication fields. Simply

enter the report code for each zone.

Comm. Defaults
¥ Communication defaults can be loaded anytime, and

does not affect non-communication program fields.

Zone Reports
¥ All 64 zones can report to a central station using any

standard reporting format.

Callback
¥ Callback defeat option for downloading.

Real-Time Clock
¥ Real-Time clock for time related functions.

NOTE: 6139 or 6139AV alpha keypad must be used
to set clock, or it can be set using Downloader
software.

AC Loss Reporting
¥ Random AC Loss and AC Restore reporting option

sends report randomly from 10-40 minutes after AC
loss, to help prevent central stations from receiving
an overload of reports due to area blackouts.

Test Reporting
¥ Intelligent test reporting option means test reports

will not be sent if any other report was sent within the
programmed test report interval.

Split/Dual Reporting
¥ Split/Dual reporting communicator options available.

Cancel Report
¥ Option to allow a cancel report to be sent, even after

Bell Time-out has ended.

Voltage Triggers
¥ Used to interface with LORRA or other devices.
¥ PC Downloader can command output voltage

triggers to pulse on for 2 seconds.

Phone Numbers
¥ Primary and secondary phone number capability.
¥ Can program different formats for each phone

number.