Fault Annunciation

Since the phone module, RF receiver(s), VIM and the polling loop are shared
among the 2 partitions, the scheme for annunciating their failure follows:

Respective faults (for zones 87, 88Ð91, 93 & 97) will report as trouble conditions
only, and as such, should be assigned either zone type 00 if no annunciation is
desired, or zone type 05 if annunciation as trouble condition is desired. If the
polling loop or RF link fails supervision, the corresponding zone number will
display a trouble condition for each partition that uses the device that failed. In
addition, all zones associated with that device will indicate a check condition. The
trouble condition will not interfere with the ability to arm the partition, but the faults
must first be bypassed.

Compatible Polling Loop

Devices

4208

Eight Zone Polling Loop Expansion Module

Does not support 2-wire smoke detectors.
Set DIP switches to identify 8 zones.

4190WH

Two Zone Remote Point Module
The left zone can be EOLR supervised, if necessary, and can
accept either open or closed circuit sensors, and can be set for
fast response. The right zone is unsupervised and can accept
closed circuit sensors only.

4278

Quad Element Polling Loop PIR
DIP switch programmable and connects directly to the polling
loop. Features an auxiliary sensor loop that permits connection of
another nearby closed circuit alarm sensor (reed contact, etc.).

4275

Dual Element Polling Loop PIR
DIP switch programmable.

4194

Surface Mounted Reed Contact (Wide Gap)
DIP switch programmable.

4 1 9 7 / 4 2 9 7

Polling Loop Extender Module
By installing a 4297 at the end of the first loop, the polling loop
can be continued. If more than 64mA needs to be drawn from the
polling loop to power RPMs, use of the 4197/4297 provides
another loop with 64mA available. See instructions accompany-
ing unit.

4192SD

Photoelectric Smoke Detector
DIP switch programmable.

4192SDT

Photoelectric Smoke Detector w/Heat Detector
DIP switch programmable.

4192CP

Ionization Smoke Detector
DIP switch programmable.

4139SN

Auto Smart Surface Mount Reed Contact
Serial number ID "enrolled" by control panel.
Check product availability.

4191SN

Auto Smart Recessed Reed Contact
Serial number ID "enrolled" by control panel.
Check product availability.

4939SN

Auto Smart Surface Mount Contact
Serial number ID "enrolled" by control panel.
Check product availability.

4959SN

Auto Smart Overhead Door Contact
Serial number ID "enrolled" by control panel.
Check product availability.

998MX

Polling Loop PIR
Serial number ID "enrolled" by control panel.

Advertising
This manual is related to the following products: