Serial Number

Enrolling/Deleting

SERIAL # PROG?
0=NO 1=YES

To enroll or delete a device's serial number, enter 1
(yes). Enter 0 to move to the Alpha Programming
menu.

ENTER ZONE NO.
00=QUIT

Enter the zone number of the device to be enrolled
or deleted. Press [*] to move to the next prompt.
Enter 00 to quit Serial Number programming.

If the device for that zone number was not
programmed as a serial number input device in the
Zone Programming menus, a prompt indicating
such will appear. Press [*] to return to the Enter
Zone No. prompt.

10 PROG AS RF: 2
A000-5372: 2

If a serial number has already been enrolled for that
device, a summary prompt will appear displaying the
type of device and its serial number. Press [*] to
continue to the Delete S/N prompt.

DELETE S/N?
0=NO, 1=YES

Enter 1 to delete the displayed serial numbered
device. Enter 0 if this device should not be deleted.

INPUT TYPE
INPUT = 0 OR 3Ð6

If a serial number for that device has not been
enrolled yet, and if the device assigned to that zone
number has been programmed as a serial number
input device in the Zone Programming menus,
this prompt will appear. Enter the device input type
as follows: 0 = none, 3 = supervised RF transmitter,
4 = unsupervised RF transmitter, 5 = RF button
type, 6 = serial polling loop device. Press [*] to move
to the next prompt.

LEARN S/N?
0=NO, 1=YES

If adding a new serial number device to the system,
this prompt will appear after entering the input type..
Enter 1 to have the system enroll the device's serial
number. To enroll the serial number at a later time but
retain the zone programming information, enter 0. If
0 is entered, a zone summary screen appears
(described later). Press [*] to return to the Enter
Zone No. prompt to enroll another device's serial
number or to exit enroll menus.

INPUT S/N:L
Axxx - xxxx:L

If 1 was entered at the Learn S/N? prompt, this
screen will appear. The device's serial number can
be manually entered as described in the Zone
Programming section on the previous page, or it can
be automatically enrolled by faulting the device at
least twice (causing 2 transmissions). Two matching
transmissions must be received. The keypad will
beep with each transmission received. Press [*] to
continue.

10 PROG AS RF:2
A000-5372:2

A summary screen will appear if the serial number
was successfully enrolled. Press [*] to continue.

10 ZT P RC IN:L

A summary screen for the zone programming will
appear showing the zone number, zone type (ZT),
partition assignment (P), report code (RC), and input
device type (IN:L). Press * to continue. The Enter
Zone No. prompt will appear again.

Advertising
This manual is related to the following products: