COMMUNICATION PROGRAMMING GUIDE

Field #

Low Speed

Contact ID

High Speed

Express

*46, *48

Choose transmission

No effect

No effect

No effect

speed and frequency

*52, *53

Send as either 4+2

No effect

No effect

No effect

or expanded

*79, *80

Enables alarm restores

Enables alarm restores

Enables alarm restores

Enables alarm restores

*49

Add checksum digit

No effect

Add checksum digit

No effect

*81, *82

Define codes and

1st digit enables report

1st digit enables report

Define codes and

selects 4+1 or 4+2

if it is non-zero

if it is non-zero

selects 4+1 or 4+2

*54, *56, *59, *61,

Defines alarm event

Enables reports

Assigns reporting channel

Defines alarm event

*64, *66, *69, *71,

code

for all reports from this zone.

code

*74, *76

Enables alarm reporting.

*55, *57, *60

Defines code and

No effect

No effect

Defines code and

*62, *65, *67,

selects 4+1 or 4+2

selects 4+1 or 4+2

*70, *72, *75, *77
*58, *63, *68,

Enables report and

Enables report

Enables report

Enables report and selects

*73, *78

selects code. Note:

Note: Alarm channel

1st digit of. the 2-digit

event

No restores if

must be programmed.

code. NOTE: No restores

event not sent.

(01-15)

if event not sent.

*50

Sescoa/Radionics;

No effect

No effect

No effect

Selects fixed digit time
instead of fixed interdigit.

NOTES

Note: Low Speed will
not send 3+2 messages.
Zone ID digit is suppressed.

Summary Of Default Consequences

Loading communication defaults results in the following:

Low Speed

( * 9 4 * 8 0 )

¥ Selects low speed, standard format with no checksum, for both phone numbers.
¥ Assigns the following report codes:

03 for zones 2-47
01 for zones 1 & 48-55 (fire zones)
02 for zones 62,63 (panic transmitter), & 95, 96, 99 (keypad panics)
09 for all alarm restores

¥ Enables all zone type alarm restores.
¥ Disables reporting Troubles, Trouble Restores, Bypass, Bypass Restores for all zones.

A D E M C O

Express

(*94*81)

¥

Selects Ademco express reporting format, with checksum, for both phone numbers.

¥

Report codes for zones 1-64, RF receivers and keypad panics are sent as their
respective zone ID numbers (01-64, 87-91, 95-99), Duress is sent as "DD". Alarm
restore is "E" + 2nd digit.

¥

Enables all zone type alarm restores.

¥

Disables reporting Troubles, Trouble Restores, Bypass, Bypass Restores for all zones.

ADEMCO High

Speed (*94*82)

¥ Selects Ademco High Speed format, with no checksum, for both phone numbers.
¥

Reporting is assigned to the following channels:

Channel 1 for zones 1 & 48-55 (Fire zones)
Channel 2 for zones 2-8
Channel 3 for zones 9-16
Channel 4 for zones 17-31
Channel 5 for zones 32-47 (RF interior zones)
Channel 6 for zones 56-61
Channel 9 for zones 62 & 63 (panic transmitter)
Channel 7 for zone 87 and for 2nd receiver (88 & 89) & polling loop short (97)
Channel 8 for first receiver (90 & 91)
Channels 10, 11 & 12 for keypad panics 95, 96 & 99 respectively

¥

Enables all zone type alarm restores.

¥

Enables Duress to be sent.

¥

Disables reporting Troubles, Trouble Restores, Bypass, Bypass Restores for all zones.

A D E M C O ' s

Contact ID

( * 9 4 * 8 3 )

¥

Selects Contact ID format for both phone numbers.

¥

Reporting is enabled for all zones.

¥

Enables all zone type alarm restores.

¥

Refer to the SYSTEM COMMUNICATION section for event code definitions.