Compatible 5800 Series

Wireless Devices

(Refer to the installation

instructions provided with

each transmitter)

5801...................

4-Button

Transmitter

5802...................

Pendant Panic Transmitter

5802CP ..............

Belt Clip Panic Transmitter

5802MN..............

Belt Clip or Pendant Panic Transmitter

5804...................

4-Button

transmitter

5806...................

Photoelectric Smoke Detector

5807...................

Photoelectric Smoke Detector

5808...................

Photoelectric Smoke Detector

5816...................

Miniature

Transmitter

5816MN..............

Miniature

Transmitter

5816TEMP .........

Low Temperature Transmitter

5817...................

3-Point

Transmitter

5818...................

Recessed

Transmitter

5827...................

Wireless

Keypad

5849...................

Glass Break Detector

5890...................

Dual Element PIR

VOLTAGE TRIGGERS (Connector J7)

(Ground St art Module, Keyswit ch, R emot e Keypad Sounder, or a non-A demco A A V Unit
requiring a Volt age t rigger)

General Information

Connector J7, located on the right hand side of the main PCB provides 4 latching

trigger outputs for operating the 675 Ground Start Module, the 4146 Keyswitch,,
a non-Ademco AAV unit, a remote keypad sounding piezo, and for triggering
auxiliary alarm signaling equipment (such as the 7720 and 7920SE LORRA
Subscriber Radios). Note that these output triggers can be enabled by partition
via programming field 2*20.

The pin assignments of this connector are shown below. Use only the 4142TR
9-wire cable (available as an option) for making connections to this connector.

1 2 3 4 5 6 7 8

9

GRAY

YELLOW

WHITE

RED

GREEN

BROWN

BLUE

BLACK

GROUND

OUT 1

GROUND

OUT 2

GROUND

OUT 3

GROUND

OUT 4

J7 CONNECTOR

OUT 1: GROUND START OR OPEN/CLOSE
OUT 2: FIRE OR KEYSWITCH ARMED LED
OUT 3: BURGLARY/AUDIBLE PANIC/AUXILIARY
OUT 4: SILENT PANIC/DURESS OR KEYSWITCH READY LED

N/U

4142TR CABLE

J7 CONNECTOR

FOR VOLTAGE

TRIGGERS

Output 1: Operates, by default, as a trigger for the 675 ground start module. This output

may optionally be programmed via field 1*46 to operate as an open/close trigger,
a remote keypad sounder output , or a trigger for an AAV unit from another
manufacturer, as follows:
1*4 6

0 = ground start module
1 = open/close trigger
2 = remote keypad sounding
3 = AAV trigger (non-Ademco AAV unit only!)

Only one of these options may be used at any time.

Rating:

When Activated: 10Ð13.8 VDC through 4K
ohms (2.5mA max).
When De-activated: 100 ohms to ground.

(Continued on next page)