Summary of connections, Vista-40 summary of connections, Р 113 р – Guardian Technologies Ademco VISTA-40 User Manual

Page 113

Advertising
background image

Р 113 Р

+

+

N.C.

N.C.

N.O.

2k EOLR

(note 1)

2k EOLR

(note 1)

+

+

+ –

BELL

SIREN

NO CONNECTION

TRANSFORMER

16.5VAC, 40VA

ADEMCO No.1361

(IN CANADA

USE No. 1361CN)

or 4300 TRANS-

FORMER IF X-10

DEVICES

WILL BE USED

Connect to

24-hr. 120VAC,

60 Hz Outlet

Red

Blk

Grn

Yel

+

+

N.C.

N.C.

2k EOLR

(note 1)

2k EOLR

(note 1)

+

+

N.C.

+

+

N.C.

N.C.

2k EOLR

(note 1,4)

TIP

(BROWN)

RING

(GRAY)

TIP

(GREEN)

RING

(RED)

Handset

Incoming

Phone Line

Telephone connections

using Ademco

direct connect cord

and RJ31X jack

(CA38A in Canada)

EARTH GROUND
Connect to good earth
ground to maintain im-
munity to transients.
See Instructions for
proper grounding.

SMOKE

4190
RPM

4278

PIR

Polling loop rating: 64mA
maximum. See Installa-
tion Instructions for
maximum number of
devices supported and
maximum wire run length.

VISTA-40 SUMMARY OF CONNECTIONS

USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS

Zone resistance (Excluding EOLR):
ZONE 1, 8: 100 OHMS MAX.
ALL OTHER ZONES: 300 OHMS MAX.

ZONE 1

ZONE 2 ZONE 3

ZONE 4 ZONE 5

ZONE 6 ZONE 7

ZONE 8 ZONE 9

2-WIRE SMOKE

DETECTOR LOOP

(Also supports NO/NC Burg contacts)

POLLING LOOP

Programmable Response

(Fast/Normal) Loop

LATCHING TYPE GLASS

BREAK DETECTOR LOOP

Data in

Data out

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

RED (

+

)

BLK (

)

Connect to

12VDC, 4AH

or 12VDC, 7AH

GEL CELL

BATTERY

CHARGING

VOLTAGE

13.7 VDC

See

Installation

Instructions for

required

battery capacity

Replace

every

3 years

NOTE:

WHEN POWERING UP

THE PANEL, PLUG THE

TRANSFORMER IN BEFORE

CONNECTING THE BATTERY.

See Installation Instructions

for type & max # of keypads,

and for max wire run length.

ALARM SOUNDER OUTPUT
10VDC-13.8 VDC,2.8A max.
Note: Combined alarm and auxilary
power output current must be limited
to 750mA for UL installations.

AUXILARY POWER OUTPUT
9.6VDC - 13.8VDC,750 mA max.
Note: Include current drawn
by keypads and polling loop
devices when making
auxiliary power calculations.

+

NOTES: 1. Zone 1 may be selected for EOLR supervised

or normally closed (no EOLR) operation via cut
jumper. (Cut red jumper for normally closed operation.
Do not cut for Fire Usage). Zones 2-8 may be selected
for either operation via program field

*41.

Zone 1 supports 2-wire smoke detectors.
See Installation Instructions for recommended type
and maximum number of detectors supported.
Zone 7 may be used for remote keyswitch arming/disarming.
See Installation Instructions for wiring instructions.

Zone 8 supports 2-wire latching type glass break detectors.
See Installation Instructions for recommended type and
maximum number of detectors supported.

2.

3.

4.

1 2 3 4 5 6 7 8 9

1. Not Used
2. Ground-
3. Out 1 (Ground Start)
4. Ground-
5. Out 2 (fire)
6. Ground-
7. Out 3 (burg/aud. panic)
8. Ground
9. Out 4 (silent panic/
duress)

Optional programming:
Out 1: Open/close or Keypad-like sounding
Out 2: Armed LED
Out 4: Ready LED

Ratings for Out 1:
Active: 10VDC-13.8VDC through 4k OHMS
Not Active: 100 OHMS to ground
Ratings for out 2-4:
Active: 10VDC-13.8VDC through 5k OHMS
Not Active: 1k OHMS to ground

N.C.

N.O.

N.O.

N.O.

2k EOLR

(note 1,2)

N.O.

N.O.

N.O.

N.C.

N.O.

2k EOLR

(note 1)

2k EOLR

(note 1,3)

N.C.

+

J7

GLASS
BREAK

1 2 3 4 5 6 7 8 9

J8

MAKE CONNECTIONS USING

No. 4142TR CABLE

WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED

Fire

Usage

Burg.

Usage

CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE
ALARM HEADQUARTERS OR A CENTRAL STATION SHALL
BE PERMITED ONLY WITH THE APPROVAL OF THE LOCAL
AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM
SIGNAL SHALL NOT BE CONNECTED TO A POLICE
EMERGENCY NUMBER.

1. I n 2
2. Ground
3. In 3 (4300 sync)
4. In 4 (4300 sync)
5. Ground
6. Out 5 (4300 data)
7. Out 6
8. Ground
9. Ground

Red Jumper

(note 1)

DOC LOAD No.: 5

J7 Header J8 Header

BATTERY

TABS

4192SD
SMOKE

WARNING: TO PREVENT

RISK OF ELECTRICAL

SHOCK, DISCONNECT
TELCO JACK BEFORE

SERVICING THIS PANEL.

THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE
WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S
STANDARD 74 (NATIONAL FIRE PROTECTION ASSOC.,
BATTERYMARCH PARK.QUINCY, MA. 02269). PRINTED
INFORMATION DESCRIBING PROPER INSTALLATION,
OPERATION, TESTING, MAINTENANCE, EVACUATION
PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.

FOR COMPLETE INFORMATION,
SEE INSTRUCTIONS N7001-INSTV2

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.

COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B

THIS DEVICE COMPLIES WITH PART 15 OF
FCC RULES. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) IT MAY NOT
CAUSE HARMFUL INTERFERENCE.
(2) IT MUST ACCEPT ANY INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.

(Refer to Installation Instructions for information concerning Direct Wire
Downloading using the 4100SM Serial Module.)

ALL CIRCUITS ARE
POWER LIMITED
.

REMOTE KEYPAD

(Addressable keypads)

Zone response time:
ZONES 1-8: 350mSec-500mSec, or 720mSec
ZONE 9: Programmable for
Fast: 10mSec-15mSec
Normal: 350mSec-500mSec, or 720mSec
(default response)

NOTE:
Zone 5 supports
AAV Triggering
(Zone Type 10)
See I.I. for Pro-
gramming and
Wiring Inform-
ation.

OPTIONAL

VOICE

INTERFACE

MODULE

(VIM)

TO
CONTROL'S
KEYPAD
TERMINALS
(6, 7, 8, 9)

SEE INSTRUCTIONS
FOR WIRING DETAILS

TO GND TERM 30

TO HANDSET
TERMINAL'S 26 & 27

{

TO

6139AV

2-WAY

VOICE

KEYPADS

(UP TO 6)

OPTIONAL
4285 PHONE
MODULE

OPTIONAL
4281/5881/5882
RF RECEIVER

SEE INSTRUCTIONS
FOR WIRING DETAILS

TO

TO:

6

7 8 9

TO: 6 7 8 9

Advertising
This manual is related to the following products: