99

Bit Device Processing Method

3

SEQUENCE PRO

G

RAM

M

ING

3.20 Bit Device Processing Method

As the processing method when the bit device (X, Y, M) is specified, 1-bit processing
and 16-bit processing using digit designation processing are available.

3.20.1 1-bit processing

When a PLC instruction is used, the device used as the target of operation processing
is one bit (one point) of bit device, and multiple bits cannot be specified.

3.20.2 Digit designation processing

When a basic or application instruction is used, the bit device used as the target of
operation processing may have to be specified by digit designation. When the
instruction whose processing unit is 16 bits is specified by this digit designation, up to
16 points can be specified in units of four points.

(1) 16-bit instruction: K1 to 4 (4 to 16 points)

Setting ranges of 16-bit data, X0 to F, by digit designation

Fig 3.25 Digit Designation Setting Range for 16-bit Instruction

(a) When there is digit designation on the source (S) side, the numerical values

that can be handled as the source data are as indicated in Table 3.6.

Table 3.6 List of Designated Digits and Numerical

Values That Can Be Handled

Number of Designated Digits

16-bit Instruction

K1 (4 points)

0 to 15

K2 (8 points)

0 to 255

K3 (12 points)

0 to 4095

K4 (16 points)

-32768 to 32767

LD XO,OUT

Example

Example

Designation range

of K1

(8 points)

(12 points)

(16 points)

(4 points)

Designation range of K2

Designation range of K3

Designation range of K4