The diagram shows the connection of a PentaScanner+ to an IDC (110) block in the wiring closet
and a 2-Way Injector+ or Super Injector+ to a Modular 8 jack in the work area.

Punch Down Block Adapter kits are available (as optional accessories) to interface the Scanners
with IDC (110) punch-down blocks. For the PentaScanner+, order kit #8123-01. For the
PentaScanner and PentaScanner Cable Admin, order kit #8051-13.

Use the 110 Block to 36-pin patch cable to attach the Scanner to the 110 Punch down block. At
the other end of the link, use the Modular 8 plug to 36-pin patch cable to attach the Injector to
the Modular 8 jack.

If you are using a 2-Way Injector or Super Injector, use the Modular 8 patch cable to connect the
Injector to the Modular 8 jack, as shown:

Full Channel Modular 8 Link

A full channel consists of the different link elements from the hub to the wallplate. For cables
terminated with a Modular 8 plug, use the Modular 8 Adapter to interface the PentaScanner+
with these cables. This diagram shows the connection of a PentaScanner+ to a cross connect in the
wiring closet and a 2-Way Injector+ or Super Injector+ to a Modular 8 jack in the work area.

Wiring Closet Work Area

Modular 8 Jack

Modular 8 Injector

36-Pin Scanner

Modular 8
Adapter

110 block

User Cable

Wiring Closet Work Area

Modular 8 Jack

110Block
to 36-Pin
Patch Cable

Modular 8 Injector

36-Pin Scanner

Modular 8
Patch
Cable

110 block