Microtest TSB-67 - 568A Annex E User Manual

Page 53

Advertising
background image

Page 53

Length

TDR method determines length and distance to cable faults

Range: 0 to maximum distance

where maximum distance

=

915 meters (3000 ft)for twisted pair cable

=

1220 meters (4000 ft) for coaxial cable

Accuracy: ± K ± Length Resolution ± NVP uncertainty

where K = ±4% of length or 0.6 meters (2 ft), whichever is greater

Length Resolution: 0.3 meters (1 ft)

PentaScanner+ NEXT and Attenuation Measurement Performance Specifications

*Notes:
(1) NEXT accuracy is calculated at the Basic Link Limit (29.3 dB) per error model in TSB-67 A.3
(2) NEXT accuracy is calculated at the Channel Limit (27.1 dB) per error model in TSB-67 A.3
(3) Performance assumes a high performance modular 8 plug
(4) Attenuation accuracy calculated per error model in TSB-67 A.3

Near-End Crosstalk (NEXT)

Tests all six pair combinations

Frequency range 0.7 to 100 MHz

Sweep Mode 0.1 MHz, 0.2 MHz, 0.5 MHz linear or TIA (user selectable)

Dynamic Range:

PentaScanner+

: Measurement dynamic range > 75 dB

PentaScanner

/

PentaScanner

Cable Admin

: At least 15 dB > 568A

Measurement Accuracy:

PentaScanner+

: Calculated per TIA TSB-67 error model (see NEXT and Attenuation

Specifications table)

PentaScanner

/

PentaScanner

Cable Admin

: 1.5 dB when measured ±1.5 dB when

measured using fixed attenuators

Measurement resolution: 0.1 dB

Attenuation

Tests all four pairs using far end active signal injection

PentaScanner+ NEXT and
Attenuation Performance
Parameters @ 100MHz

Testing through
36-Pin Connector

Testing
through
Mod 8
Adapter

Typical

Typical

Max

Dynamic Accuracy (dB) 0.3 0.5 0.3

Residual NEXT (dB) 67 62 45

Output Signal Balance (dB) 50 43 40

Common Mode Rejection (dB) 45 38 34

Random Noise (dB) 78 75 78

Transmit Return Loss (dB) 26 23 20

Receive Return Loss (dB) 22 17 17

NEXT Accuracy (dB) @ 100 MHz 0.5 (*1) 0.9 (*1) 1.5 (*2,3)

Atten. Accuracy (dB) @ 100 MHz 0.3 (*4) 0.6 (*4) 0.6 (*3,4)