Chapter 6: Measure Cable Performance

Measure Cable Performance

lets you run individual tests such as NEXT, Attenuation,

Length/Delay, Impedance, Loop Resistance, Capacitance, Impulse Noise and Peak to Peak Noise.

Press the Measure Cable Performance key to display a list of the tests to run.

Press the

Ñ

or

Ò

arrow key to highlight the test you want to run, then press

Select (F1)

to run

the highlighted test.

Press the

ESCAPE

key to return to the Ready screen.

See Chapter 3: Autotest for more information on test results for UTP cable.

See Appendix D: Working with Coaxial Cable for information on test results for coaxial cable.

NEXT

To display this screen, press the

Measure Cable Performance

key, then select

NEXT

.

This screen displays the frequency sweep range and the worst case NEXT for each pair. When using
the

2-Way Injector+

or

2Way Injector

, the top line of the screen indicates if NEXT is being

reported from the Scanner end (

Penta

) or the Injector end (

Inj

) of the link.

Press

Graph (F1)

to enter graphing mode.

Press

Sweep (F2)

to display the NEXT Sweep range and step criteria.

Press

Pair (F3)

to toggle through the available pair combinations.

When using the

2-Way Injector+

or

2Way Injector

, press

F4

to toggle between the NEXT results

for the Injector end or the Scanner end of the link.

Press the

ESCAPE

key to return to the

MEASURE CABLE PERFORMANCE

screen.

NEXT Graph

To display this screen, press the

Measure Cable Performance

key, then select

NEXT

, then press

Graph (F1).

The top line of the screen displays the worst case NEXT and the frequency at which it occurred.

When using the

2-Way Injector+

or

2Way Injector

, the second line of the screen indicates if

NEXT is being reported for the Scanner (

Penta

) or Injector (

Inj

) end of the link.

Press

Zoom (F1)

to magnify the area of the graph around the cursor. The Zoom key can display

1x, 2x, 5x or 10x magnification.

Press

Print (F2)

to print the NEXT graph.

Press

Test (F3)

to rerun the NEXT test and display new data.

Press the

ESCAPE

key to return to the

NEXT

results screen.