Customizing next limits, Next test results – Microtest TSB-67 - 568A Annex E User Manual

Page 22

Advertising
background image

signal and the difference is reported as the NEXT value (in dB). When measuring Injector end
NEXT, the roles of the devices are reversed. The Scanner provides the 100 ohm termination for
the Injector measurements and the Injector transmits a signal which is varied (or swept) through a
frequency range. The signal is monitored by the Injector on the receive pair through a narrow band
receiver and the difference in the transmitted and received signal levels is reported as the Injector
end NEXT (in dB).

Customizing NEXT Limits

To display the

NEXT LIMITS

screen, press the

Extended Functions

key, then select

Setup

Autotest

, then highlight the Autotest to edit, then press

Edit (F2),

then select

Limits

, then select

NEXT

.

The

NEXT LIMITS

screen lets you specify the PASS/FAIL limits, frequency range and step size

used in testing NEXT. Press the

Ñ

or

Ò

arrow key to select the NEXT limit to be changed.

The selected limit will be enclosed in a box.

If your Scanner has an alphanumeric overlay on the keypad, use the keypad to enter the limit. If
your Scanner does not have an alphanumeric overlay, press

Edit (F2)

to display the edit screen.

Note:

Limit

only applies when

Criteria

is set to

Fixed

. When

Criteria

is set to

Fixed

, the decibel

value entered in the Limit field will be used as the PASS/FAIL criteria across all frequencies.

The

PentaScanner+

allows you to set a limit based on an

Offset

value. When

Criteria

is set at

something other than

Fixed

, the

Offset

field replaces the

Limit

field. The value entered in the

Offset

field will be added to the NEXT criteria calculations, allowing you to set tighter NEXT

limits in your Autotests. For example, if you enter a dB offset of 5.0 dB, the criteria calculations for
Cat 5 Link, Cat 5 Channel, etc. will be increased by 5.0 dB. You can enter offset values from 0.0
— 60.0 dB.

When

Step

or

Criteria

is selected,

Change (F2)

lets you toggle through the available settings.

After editing, press

Save (F1)

to store the new NEXT limit settings and exit or press the

ESCAPE

key to exit without saving.

NEXT Test Results

To display the

NEXT

screen, press

View (F1)

from the

AUTOTEST RESULTS

screen, then press

the

Ò

key until the

NEXT

screen is displayed. This screen displays Near End Crosstalk (NEXT)

test results.

When using the

2-Way Injector+

(or the

2-Way Injector

), the top line of the screen indicates if

NEXT is being reported for the Scanner (

Penta

) or Injector (

Inj

) end of the link.

At the upper left of the screen, the pair combination is shown. The PASS/FAIL bar across the
screen compares the measured NEXT value to the NEXT limit value. The Autotest name is
displayed after

Spec:

at the lower left of the screen.

Press

Detail (F1)

to display the Frequency Sweep range and test results for all pairs.

Press

Pair (F3)

to toggle through the NEXT results for each pair combination.

When using the

2-Way Injector+

(or the

2-Way Injector

), press F4 to toggle between NEXT

results for the Scanner (

Penta

) or Injector (

Inj

) end of the link.