Wire map for both ends of the link – Microtest TSB-67 - 568A Annex E User Manual

Page 41

Advertising
background image

Page 41

Wire Map for Both Ends of the Link

The Injector plays an integral part in determining the wire map for a given link. With the
Scanner and the Injector connected at opposite ends of a link or cable, the wire map can be
determined. When running

Find Cable Faults

or

Autotest

, the Scanner and the Injector

communicate to determine how the link is wired. With the wire map on display, press

Splits (F1)

to

display the wire splits screen. The Scanner/Injector combination identifies the following wiring
configurations:

Straight Through Wiring

Straight through wiring (the expected case) is displayed as shown:

Cross Wiring

Cross wiring is displayed as shown:

Short at the Injector End

A short at the Injector end is displayed as:

S

hort at the Scanner End

A short at the Scanner end is displayed as:

Note: The Injector is not required in order to detect a short at the Scanner end of the link.

Short on the Link

A short in the link (where wires can be seen at both ends) is displayed as:

Advertising