Length/delay test results, Impedance test results, Loop resistance test results – Microtest TSB-67 - 568A Annex E User Manual

Page 60: Capacitance test results

Advertising
background image

By pressing the

Measure Cable Performance

key, you can test Length/Delay, Impedance, Loop

Resistance, Capacitance, Impulse Noise and Peak-to-Peak Noise for coaxial cable. NEXT and
Attenuation are not supported for coaxial cable.
NOTE: The Injector is not used when testing coaxial cable.

Length/Delay Test Results

To display the

LENGTH/DELAY

screen, from the

Ready

screen, press

Jack (F4)

and set the Jack

to Coax. Then press the

Measure Cable Performance

key, then select

Length/Delay

.

During the Length/Delay test, the cable should be open or shorted.

If

NEF

(No End Found) is displayed next to the Length, it indicates that the cable is properly

terminated or the cable is too long.

The IEEE Length specification is 600 feet.

Press the

ESCAPE

key to exit.

Impedance Test Results

To display the

IMPEDANCE

screen, from the Ready screen, press

Jack (F4)

and set the Jack to

Coax. Then press the

Measure Cable Performance

key, then select

Impedance

.

During the Impedance test, the cable can be open, shorted or terminated. There is no preference.

If

UND

(Under range) is displayed, the cable is less than 40 feet long or the Impedance is less than

40 ohms.
If

OVR

(Over range) is displayed, the Impedance is greater than 200 ohms, the cable is less than

40 feet long, or the cable/pair is not connected.

The IEEE Impedance specification is 50 ohms, ±2 ohms.
Press the

ESCAPE

key to exit.

Loop Resistance Test Results

To display the

LOOP RESISTANCE

screen, from the

Ready

screen, press

Jack (F4)

and set the

Jack to Coax. Then press the

Measure Cable Performance

key, then select

Loop Resistance

.

During the Loop Resistance test, the cable should be terminated or shorted.

If

OVR

(Over range) is displayed, the Loop Resistance is greater than 10K ohms.

The IEEE Loop Resistance specification is 14.6 ohms.

Press the

ESCAPE

key to exit.

Capacitance Test Results

To display the

CAPACITANCE

screen, from the

Ready

screen, press

Jack (F4)

and set the Jack to

Coax. Then press the

Measure Cable Performance

key, then select

Capacitance

.

During the Capacitance test, the cable should be open.

Advertising