Selecting pairs for autotest, Selecting tests to run during autotest – Microtest TSB-67 - 568A Annex E User Manual

Page 17

Advertising
background image

Page 17

When Margin Display is set to

TIA Margin Display

, marginally passing test results (those for

which the passing value falls within the Scanner’s accuracy range) are marked with “*PASS”. When
Margin Display is set to

ACR Margin Check

, a cable will pass if a failing NEXT test result is within

the Scanner’s accuracy range AND if the ACR result is within an acceptable range. When Margin
Display is set to

None

, the only possible Autotest results are “PASS” or “FAIL”.

In the Autotest memory list screen, the test status can be “P” (PASS) or “F” (FAIL), or if the
Autotest was run with Margin Display set to

TIA

, “*” (MARGINAL PASS).

After editing, press

Save (F1)

to store the new Autotest name and exit or press the

ESCAPE

key

to exit.

Selecting Pairs for Autotest

To display the

EDIT AUTOTEST PAIRS

screen, press the

Extended Functions

key, then select

Setup Autotest

, then highlight the Autotest to edit, then press

Edit (F2);

then select

Pairs

. This

screen lets you select which pairs to test and which pairs to use as PASS/FAIL criteria.

The top row indicates the pairs to be tested during Autotest. The bottom row indicates the pairs
that will determine the PASS/FAIL criteria for the cable. Press the

Ï

or

Ð

arrow key to

move left or right within the rows. Or, press the

Ñ

or

Ò

arrow key to move between rows.

Press

Select (F2)

(or

Unsel

) to select (or deselect) the pair. Selected tests are marked with an ‘x’.

Press

Save (F1)

to store the pair selections and exit or press the

ESCAPE

key to exit without

saving.

Note: If a pair is selected for PASS/FAIL criteria, but is not selected for testing, all tests will fail. If
a pair is selected for testing but is not selected for PASS/FAIL criteria, the Autotest will not be
marked as FAIL if that pair fails.

Selecting Tests to Run During Autotest

To display the

EDIT TESTS TO RUN

screen, press the

Extended Functions

key, then select

Setup Autotest

, then highlight the Autotest to edit, then press

Edit (F2),

then select

Tests to

Run

. This screen lets you enable or disable the tests to run during Autotest. When using the

2-

Way Injector+

or

2-Way Injector,

you can run tests at the Scanner or Injector end of the link.

Press the

Ò

or

Ñ

arrow key to highlight the test(s) to enable or disable.

Press

Select (F2)

(or

Unsel

) to enable (or disable) the highlighted test. Enabled tests are marked

with an ‘x’.

After all test selections have been made, press

Save (F1)

to save the list of selected tests for this

Autotest.

Press the

ESCAPE

key to exit the screen without saving.

Note: ACR will not be computed unless the NEXT and Attenuation tests are enabled (since ACR
computations are based on NEXT and Attenuation measurements). The Scanner will automatically
disable ACR if NEXT or Attenuation is not enabled.