Page 55

High Voltage Input/Protection

The test interface withstands input hazard conditions that arise from normal telephone
interfaces (48 VDC at less than 80 mA) or 24 VAC power used to power many telephone
keysets.

2-Way Injector+/2-Way Injector

Environmental, Physical Characteristics, User Interface, Measurement Port

Refer to specifications for

PentaScanner+

/

PentaScanner

/

PentaScanner

Cable Admin

LED Displays

Pass Indicator (GREEN) for test result

Fail Indicator (RED) for test result

Status Indicator (GREEN) for 2-Way Injector status

Charging Indicator (RED) for battery status

Hazard Indicator (RED) for high voltage input protection warning

Audible Feedback

Programmable tone generation through a piezo-electric transducer to signal test is complete or
overvoltage conditions

Rechargeable Battery

Removable, rechargeable Nickel Cadmium (Ni-Cd)

Capacity:

1200 mAh

Battery Life:

8+ hours daily operation

Charging Time:

14 hours (via AC Adapter)
2-3 hours (via Battery Charger)

High Voltage Input/Protection

The test interface withstands input hazard conditions that arise from normal telephone
interfaces (48 VDC at less that 80 mA) or 24 VAC power used to power many telephone
keysets.

FLASH Memory

128K FLASH memory is provided to allow for software updates in the field

Power Control

AC Adapter or Battery

Auto-shutoff when operating on battery

Power on under Scanner control

Injector End Termination to Support Scanner Measurements

OPEN (during Impedance, Capacitance, and Length measurements and during
Communication)

SHORT (during Loop Resistance measurements)

100 Ohm Termination (during NEXT measurements)

Swept signal injections during Autotest

Advertising