4.

Begin the transfer from the Scanner (see step 7 in Printing or Downloading Test
Results

, above). Select “text” as the Print Format. You should see the information

scrolling on the Procomm Plus window while the transfer is in progress.

5.

When the transfer is complete, press

ALT + F1

again to close the log file. The file will

be saved under the current directory.

6.

Press

ALT + X

to exit the Procomm Plus package.

You can now use the DOS ‘COPY’ command to print the log file to a printer; i.e., “COPY
filename.txt LPT1”.

Procomm Plus for Windows

To send reports to a PC using Procomm Plus for Windows, open Procomm Plus and perform these
steps:

1.

Press

ALT + S

to select terminal options. Ensure that the handshake method selected is

SOFTWARE, set the port to be used (COM1 or COM2). Set the data bits (8), stop
bits (1) and parity (None), and set the baud rate to the highest speed that your system
will support. Set the terminal setting to VT100. Set the protocol to ASCII. Save the
new settings.

2.

On the Scanner, press the

Extended Functions

key, then select

Printer Port

. Set the

baud rate to match the baud rate set in Procomm Plus and set the handshake to
XON/XOFF.

3.

Select the download folder. Type the desired file name. Give the filename a “.TXT”
extension to make it easy to locate.

4.

Begin the transfer from the Scanner (see step 7 in Printing or Downloading Test
Results

, above). Select “text” as the Print Format. You should see the information

scrolling on the Procomm Plus window while the transfer is in progress.

5.

When the transfer is complete, click OK.

6.

Exit Procomm Plus.

You can now use the DOS ‘COPY’ command to print the report file to a printer; i.e., “COPY
filename.txt LPT1”.

Uploading NEXT and Attenuation Graphs to a PC with Procomm Plus

Procomm Plus for DOS

1.

Open the Procomm Plus application.

2.

Press

ALT + P

to enter port parameters. Set the port to be used (COM1 or COM2),

the baud rate (default is 9600), the data bits (8), stop bits (1) and parity (None). Press

Alt + S

to save settings.

3.

On the Scanner, press the

Extended Functions

key, then select

Printer Port

. Set the

baud rate to match the baud rate set in Procomm Plus and set the handshake to
RTS/CTS. Press

F3 (Printer)

to display and change the Graphics Printer options. Save

these changes.

4.

In Procomm Plus, press

Alt + S

to get to the Procomm Plus setup utility.

5.

On the Procomm Plus setup utility menu select

FILE/PATH OPTIONS

. On the

FILE/PATH OPTIONS menu

select C- Default path for downloaded files

(PgDn) x:directory path

. Make sure the path specified is the one to which you would

like to save the files.

6.

Press

ESC

to return to the Procomm Plus Setup Utility menu.

Select TERMINAL

OPTIONS

. On the

TERMINAL OPTIONS

menu, set

C-Soft flow ctrl (XON/XOFF)