Editing Test Limits

To display the

EDIT LIMITS

screen, press the

Extended Functions

key, then

select Setup

Autotest

, then highlight the Autotest to edit, then press

Edit (F2),

then select Limits. This screen

lets you specify the PASS/FAIL limits used in tests.
Press the

Ñ

or

Ò

arrow key to highlight the test for which you want to edit the limits.

Press

Select (F1)

to display the limits screen for the highlighted test. Or, press the number on the

keypad that corresponds to the test for which you want to change the limits.
After editing the selected limits, press

Save (F1)

to save these changes and to return to the

EDIT

LIMITS

screen.

If you have created a new Autotest by editing the Autotest name or by editing a factory-
programmed Autotest, and if you want the new test to be the default Autotest, press

ESCAPE

until you return to the

AUTOTEST SETUP

screen, then press

Default (F1).

Note: See the individual test sections for information on customizing specific test limits.

Running Autotest

To display the

AUTOTEST:

screen, press the

AUTOTEST

key. This screen is displayed while

Autotest is running. The Autotest name is displayed at the top of the screen and the cable type is
shown in the top center of the screen. Each pair being tested is displayed in the lower left corner of
the screen. The name of each test being run is displayed in the lower right corner of the screen. A
status bar at the bottom of the screen indicates the progress of the Autotest.

Press the

ESCAPE

key at any time to cancel the Autotest.

Note: The Injector must be attached to the far end of the cable during Autotest. If it is not, the
Scanner screen will display the following:
Searching for Injector . . . (Injector Not Found)

Autotest Results Screen

To display the

AUTOTEST RESULTS

screen, press the

AUTOTEST

key, or press

the Extended

Functions

key and select

Memory

. This screen is displayed when Autotest completes or when

saved Autotest results are selected for viewing.

The Autotest name is at the top right of the display and the PASS/FAIL indicator is in the center.
The number of failed tests, if any, is displayed next to the PASS/FAIL indicator. An Autotest will
PASS if all the selected tests meet the specified criteria. An Autotest will FAIL if one or more
selected tests fail. When the Margin Display is set to

TIA Margin Display

an Autotest will

marginally PASS (*PASS) if one or more NEXT, Attenuation or Length measurements marginally
passes. A marginal PASS is defined as a PASS result that is closer to the PASS/FAIL threshold than
the accuracy of the Scanner.

Press

View (F1)

to display Autotest results, then use the

Ñ

or

Ò

arrow keys to scroll through

the tests. The tests you view depend on the tests you have selected to run in

AUTOTEST SETUP

.

See Selecting Tests to Run During Autotest for more information.

Press

Save (F2)

to save test results and exit. See Saving Autotest Results for more information.

Note: The

Save (F2)

key is unavailable when viewing the

AUTOTEST RESULTS

screen via the

Extended Functions/Memory

feature.