Next detail, Next graph, Attenuation – Microtest TSB-67 - 568A Annex E User Manual

Page 23

Advertising
background image

Page 23

Press the

Ñ

or

Ò

arrow key to view the previous or next test results screen.

Press the

ESCAPE

key to return to the

AUTOTEST RESULTS

screen.

Note: For diagnostic purposes, you can run NEXT continuously by pressing the

Measure Cable

Performance

key and selecting

NEXT

.

NEXT Detail

To display this screen, press

Detail (F1)

from the

NEXT

screen. This screen displays the frequency

sweep range and the worst case NEXT for each pair.

Press

Graph (F1)

to enter graphing mode.

Graph (F1)

is available when

Save Sweep Data

has

been selected in the

AUTOTEST SETUP

, or when NEXT results are viewed immediately after

running the test.

Press

Pair (F3)

to toggle through the available pair combinations.

When using the

2-Way Injector+

(or the

2-Way Injector

), press

F4

to toggle between NEXT

results for the Scanner (

Penta

) or Injector (

Inj

) end of the link.

Press the

ESCAPE

key to return to the

NEXT

screen.

NEXT Graph

To display this screen, press

Detail (F1)

from the

NEXT

screen, then press

Graph (F1).

This screen

displays the NEXT graph for the indicated pair combination.

The top line of the screen displays the worst case NEXT and the frequency at which it occurred.

When using the

2-Way Injector+

(or the

2-Way Injector

), the second line of the screen indicates

if NEXT is being reported for the Scanner (

Penta

) or Injector (

Inj

) end of the link.

Press

Zoom (F1)

to magnify the area of the graph around the cursor. The Zoom key can display

1x, 2x, 5x or 10x magnification.

Press

Print (F2)

to print the NEXT graph.

Press the

ESCAPE

key to return to the

NEXT

DETAIL

screen.

Attenuation

The Attenuation function measures signal loss in a cable as a function of frequency. This
measurement is a very important cable certification parameter. Your Scanner measures cable
attenuation using the one way method as specified by IEEE and EIA.

The one way Attenuation measurement requires that a signal be injected at one end of the cable
and measured at the other end to determine cable loss. The Injector acts as the far end signal
generator and the Scanner NEXT receiver measures the received signal.