Super injector+/super injector battery, Test connectors – Microtest TSB-67 - 568A Annex E User Manual

Page 5

Advertising
background image

Page 5

To put your

2-Way Injector

or

2-Way Injector+

into Refresh Mode, first attach the Injector to

your Scanner with a RJ-45 or 36-pin cable, whichever is appropriate for your equipment (you may
need to use an adapter if your units have different connector types). Attach the Scanner to the PC
with a DB 9 serial cable. Attach AC Adapters to both the Injector and the Scanner, and power
both units on. At the PC’s DOS prompt, type:

PENTA -2REFRESH -C1 (for COM1, or -C2 for COM2)

and press Enter. The Injector is now in

discharge mode, indicated by the alternate flashing of the Pass and Fail LED indicators. When the
battery has discharged, the Injector will switch to recharge mode (indicated by the Charging light).
To refresh the Scanner and the Injector batteries at the same time, follow the instructions above for
connecting the Injector to the Scanner, and the Scanner to the PC. Attach AC Adapters to both
the Injector and the Scanner, and power both units on. Put the Injector into refresh mode first, by
typing:

PENTA -2REFRESH -C1 (for COM1, or -C2 for COM2)

and press Enter.

Now, put the Scanner into refresh mode by typing:

PENTA -REFRESH -C1 (for COM1, or -C2 for COM2)

and press Enter.

Both units will discharge and recharge as described above.

Once the units are in Refresh Mode, you can disconnect the DB-9 serial cable. Keep the units
plugged in to the AC adapters. The units will discharge and recharge in approximately 15-20
hours. For best results, do not remove the AC adapter until the battery is fully charged. On the

PentaScanner

+, the battery is fully charged when the “Charging Battery” message is no longer

displayed on the screen. On the

2-Way Injector+/2-Way Injector

, the battery is fully charged

when the Charging Indicator LED is flashing.

Super Injector+/Super Injector Battery

The

Super Injector+

and

Super Injector

are powered by three AA alkaline batteries. (Be sure to

use only AA alkaline batteries in the Injector. Other battery types are not supported.) To remove
the batteries, move the battery door latch forward and remove the battery door.
The Injector battery life varies depending on usage and battery quality. On average, the batteries
will withstand testing of more than 500 cables. Low battery detection is reported in several ways:

The Injector Status Indicator blinks slowly (approximately once per second) instead of normal
rapid blinking.

Press the

Extended Functions

key and select

Injector Info

to display the battery status.

The Scanner checks the Injector batteries before running selected tests and before calibrating
the Injector, and displays a warning message if the Injector batteries are low.

Test Connectors

The

PentaScanne

r

+, 2-Way Injector+

and

Super Injector+

have 36-pin connectors. The

PentaScanner

, PentaScanner Cable Admin, 2-Way Injector and

Super Injector

have Modular

8 (RJ-45) connectors:

36-pin connector

Modular 8 (RJ-45) connector

on the

2-Way Injector+

on

the

2-Way Injector+

and

and the

Super Injector+

the

Super Injector