High voltage protection, Way injector+/2-way injector led indicators – Microtest TSB-67 - 568A Annex E User Manual

Page 6

Advertising
background image

High Voltage Protection

The

PentaScanner

+/

PentaScanner

/

PentaScanner Cable Admin, 2-Way Injector+/2-Way

Injector

and

Super Injector+/Super Injector

are designed to withstand input hazard voltage

conditions that arise from normal telephony applications such as 48 VDC at less than 80 ma or 24
VAC used to power many keysets. The unit detects when a voltage of greater than ±15 volts is
applied on the inputs and sounds a warning to alert the user to remove the hazard condition
immediately to prevent possible damage to the input circuits. Tests cannot be performed when
hazard conditions are detected on the inputs.

2-Way Injector+/2-Way Injector LED Indicators

Test Connector
(36-pin on 2-Way
Injector+ or Mod 8
on 2-Way Injector)

Pass
Indicator

Status
Indicator

Fail
Indicator

Circuit
Guard
Indicator

Charging
Indicator

Indicator

State

Description

Pass

Steady Light

Overall Autotest result is PASS

Fail

Steady Light

Overall Autotest result is FAIL

Status

Steady Light

The Injector is powered ON and waiting for
communication with the Scanner.

Status

Off

The Injector is powered OFF (or charging battery
if AC adapter is attached).

Status

Rapid Blink

Executing command or measurement in progress

Advertising