6. setting crater sequence display, 7. setting retract sequence display – Miller Electric Welder User Manual

Page 104

Advertising
background image

OM-196 188 Page 98

1

Crater Parameters Display

Parameter ranges are as follows:

Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.

Volts, 10.0-38.0 Volts.

Wire Feed Speed, 50 to 780 inches
per minute, IPM.

Go to Section 11-7.

> Cratr

0.02 Sec
24.0 Volt
90 IPM

Cratr
0.12 Sec

> 18.0 Volt

90 IPM

Cratr
0.12 Sec
18.0 Volt

> 200 IPM

Cratr

> 0.12 Sec

24.0 Volt
90 IPM

> Cratr

0.12 Sec
18.0 Volt
200 IPM

1

11-6. Setting Crater Sequence Display

Set Desired Time

Parameter

Select

Increase/

Decrease

Increase

Proceed to next Section.

Parameter

Select

Parameter

Select

Set Desired

Voltage

Increase/

Decrease

Parameter

Select

Set Desired Wire

Feed Speed

Increase/

Decrease

1

Retract Parameter Display

Parameter range is as follows:

Seconds, 0-1.00 seconds. If value
set is zero (0), there is no Burnback
sequence.

IPM 50-780 (1.3-19.8 mpm). Speed
is program dependent.

Go to Section 11-8.

1

> Rtrct

150 IPM
0.00 Sec

Rtrct

> 150 IPM

0.00 Sec

Rtrct

120 IPM

> 0.00 Sec

11-7. Setting Retract Sequence Display

Set Desired Speed

Parameter

Select

Parameter

Select

Increase/

Decrease

> Rtrct

130 IPM
0.12 Sec

Parameter

Select

Increase

Proceed to next Section.

Set Desired Time

Increase/

Decrease

Advertising