OM-196 188 Page 111

14-7. Selecting Arc Start Method

Arc Start selection is not used when welding in non-pulsed MIG.

Do not use the Hot Start setting for .035 in (9 mm) or smaller wire.

NOTE

ArcStart
Type

> Hot Start

1

Standard Start

Welding operation is performed at
set values for welding parameters.

2

Hot Start

Use the Hot Start mode for pulse
welding when high initial weld
current is necessary to start large
diameter welding wires. When in
Hot Start, welding power source
starts the arc in the CV mode and
switches to CC once the arc is
started.

3

Soft Start

Use the Soft Start mode for .035 in
(9 mm) or smaller wire. Low wire
feed speeds may also require the
Soft Start mode. Arc start is at 75%
of maximum amperage for pulse
welding and once an arc is
established, welding is performed
at set parameter values.

1

Aux Output
Voltage

> ArcStart

Arc Time

Pulse
ArcStart

> Standard

ArcStart
Type

> SoftStart

Press Mode

Select

Increase

Access

Setup

Display

2

3

1

Arc Time Display

The unit accumulates arc hours up
to 9999.99 hours or 999999 weld
cycles before rolling over to zero
(0). The arc timer can be reset using
this display or by performing a total
reset (see Section 14-12).

1

Voltage
ArcStart

> Arc Time

Wirefeed

0 .00 Hrs
0 Cycl

> No Reset

0.00 Hrs
0 Cycl

> Reset

Press

14-8. Resetting Arc Time

Press Mode

Select

Increase

Access

Setup

Display

Advertising