5. setting retract on/off, 6. setting sharp start on/off – Miller Electric Welder User Manual

Page 128

Advertising
background image

OM-196 188 Page 122

15-5. Setting Retract On/Off

1

Retract Display

Settings allow user to turn the re-
tract feature On or Off. The retract
feature allows the user to set a time
and wire feed speed to pull wire
away from work when the weld is
done.

Use Increase or Decrease button to
change setting. If the retract feature
is turned On, a weld sequence step
is added in the process screens.

Press Mode Select button to go to
next parameter or cycle power off
and back on at power switch to sav-
e setting and exit Control menu.

1

Access

Control

Display

Increase/
Decrease

>Process

Sequence
SharpArc
Card

> Prg 1

Pulse
035” Steel
Argon – Oxy

Adaptive
AutoConfig

> Retract

ShrpStrt

> Retract

On

Mode

Select

Or

> Retract

Off

Go To

Section 15-6

Power
Switch

Press Mode

Select

15-6. Setting Sharp Start On/Off

1

Sharp Start Display

Settings allow user to turn the sharp
start feature On or Off.

.

Sharp start should normally be
left On. The ability to turn sharp
start Off is provided in case the
user experiences problems
with weld ends using flux cored
wires.

Use Increase or Decrease button to
change setting.

Press Mode Select button to go to
next parameter or cycle power off
and back on at power switch to sav-
e setting and exit Control menu.

1

Access

Control

Display

Increase/
Decrease

>Process

Sequence
SharpArc
Card

> Prg 1

Pulse
035” Steel
Argon – Oxy

AutoConfig
Retract

> ShrpStrt

Exit

> ShrpStrt

On

Mode

Select

Or

> ShrpStrt

Off

Go To

Section 15-4

Power
Switch

Press Mode

Select

Advertising