13. selecting arc start/volt sense error shutdown – Miller Electric Welder User Manual

Page 120

Advertising
background image

OM-196 188 Page 114

1

No Reset

Press Parameter Select button to
exit memory reset parameter with-
out resetting any data.

2

Program Reset

Press Parameter Select button to
reset last active program to original
factory program settings. All other
program and setup information
remains the same. If setup card is in
card slot, program will be loaded
from card.

3

System Reset

Press Parameter Select button to
reset programs and setup to
original factory settings. System,
Arc Time, and Robot Control
settings are not affected by the
system reset. If setup card is in
card slot, program will be loaded
from card.

4

Total Reset

Press Parameter Select button to
reset programs and setup to origi-
nal factory settings for all programs
and setup including System and
Arc Time. If setup card is in card
slot, program will be loaded from
card.

5

Reset (Default) Displays

Wiretype
Display

> Memory

Shutdown

> No Reset

> Program 1

Reset

Press

> Process

Sequence
SharpArc
Card

> Prg 1

Pulse
035” Steel
Argon – Oxy

1

2

5

> System

Reset

Press

3

14-12. Resetting Memory

Press Mode

Select

Parameter

Select

Increase/

Decrease

Parameter

Select

Increase/

Decrease

Access

Setup

Display

> Total

Reset

Press

4

Parameter

Select

Increase/

Decrease

1

Voltage Shutdown Display

With Arc Start/Volt Sense on, the
unit shuts down when no arc
voltage is sensed. If the unit shuts
down, an error message appears
(see Section 5-5).

With Arc Start/Volt Sense off, the
unit continues to feed wire even
when there is no arc voltage
sensed.

Display
Memory

> Shutdown

Name

Arc Start/
Volt Sense

> On

1

Arc Start/
Volt Sense

> Off

14-13. Selecting Arc Start/Volt Sense Error Shutdown

Press Mode

Select

Increase

Access

Setup

Display