Miller Electric Welder User Manual

Page 32

Advertising
background image

OM-196 188 Page 26

5-3.

Removing Case and Measuring Input Capacitor Voltage

Turn Off welding power source, and
disconnect input power.

1

Outside Handle Screws

To loosen top, remove two outside
handle screws from both handles
and all side bolts.

2

Interconnect Board PC2

3

Voltmeter

Measure the dc voltage across the
screw terminals on PC2 as shown
until voltage drops to near 0 (zero)
volts.

Proceed with job inside unit. Rein-
stall cover when finished.

Tools Needed:

5/16 in

Ref. 801 914 / Ref. 801 917

Y

Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.

2

3

+ lead to lower right

terminal, – lead to

upper right terminal

1

1

Advertising