1. weld cycle for pulse welding, 2. setting preflow sequence display – Miller Electric Welder User Manual

Page 94

Advertising
background image

OM-196 188 Page 88

SECTION 9 – GETTING STARTED FOR PULSE WELDING

Ref. S-0271

9-1.

Weld Cycle For Pulse Welding

Wire

Speed

Weld

Start

Start

Power

Start

Speed

Preflow

Time

Arc

Strike

Weld

Speed

Weld Time

Weld

Stop

Crater Time

Crater

Speed

Arc
Out

Retract Time

Postflow

Time

Time

Run-In
Setting

Robot

Motion

.

The type of robot connected determines what
combination of parameters are available.

Run-In

WFS

9-2.

Setting Preflow Sequence Display

1

Mode Select Button

When unit is turned On, Process is
the default mode, at other times,
use mode select button to select
Sequence.

2

Parameter Select Button

Use parameter select button to
select parameters.

3

Preflow Parameters Display

Preflow can be adjusted from 0-9.9
seconds. If value set is zero (0),
there is no Preflow sequence.

Go to Section 9-3.

3

> Prflw

0.0 Sec

Prflw

> 0.0 Sec

> Prflw

1.2 Sec

2

Process

> Sequence

SharpArc
Card

> Prflw

0.0 Sec

1

Mode Select

Parameter

Select

Parameter

Select

Parameter

Select

Set Desired Time

Increase/

Decrease

Increase

Proceed to next Section.

Advertising