OM-196 188 Page 110

1

Mig Type Display

With DVC Voltage Correction On,
the unit uses closed-loop feedback
or voltage sensing leads to
maintain set voltage parameters.

With DVC Voltage Correction Off,
feedback from the arc is not used
for closed-loop feedback to
maintain voltage parameters.
Feedback from the arc is still used
for other functions.

Be sure voltage sensing leads are
connected.

1

MIG

Voltage
Correction

> DVC Off

Access

> Mig Type

Aux Out
Voltage

14-4. Selecting Voltage Correction

Press Mode

Select

Increase

Access

Setup

Display

MIG

Voltage
Correction

> DVC On

1

Auxiliary Output

This output can be set to several
conditions:

On whenever the wire feeder is op-
erating

On during the welding arc until arc
goes out

On during the entire weld cycle

Off or never On.

1

Access
Mig Type

> Aux Out

Voltage

Aux
Turn On

> w/Feeder

14-5. Selecting Auxiliary Output

Access

Setup

Display

Press Mode

Select

Increase

Increase

Aux
Turn On

> w/Arc

Aux
Turn On

> w/Weld Cyc

Increase

Aux
Turn On

> Never

1

Voltage Feedback Display

The Internal setting allows the unit
to obtain voltage feedback directly
from the welding power source out-
put terminals.

When using the V. Sense setting,
arc voltage feedback is through the
voltage sense leads connected to
the feeder. Use this setting when
there is more than 50 ft (15 m) of
weld cable used or when using
Touch Sensor.

Mig Type
Aux Out

> Voltage

ArcStart

Control
Feedback

> Internal

1

Control
Feedback

> V Sense

14-6. Selecting Voltage Sensing Method

Access

Setup

Display

Increase

Press Mode

Select