2. lower front panel controls, 3. meter functions – Miller Electric Welder User Manual

Page 27

Advertising
background image

OM-196 188 Page 21

System Reset

By selecting system reset in the memory reset mode, the unit defaults to original factory settings for
all programs and all set up excluding System, Arc Time, and Model Type.

Voltage (Control Feedback)

Allows voltage to be monitored at the output terminals by two methods. This can be selected through
the internal connections of the unit, or through the unit’s external voltage sense lead.
When using the V. Sense setting, arc voltage feedback is through the voltage sense leads connected
to the feeder. Use this setting when there is more than 50 ft (15 m) of weld cable used.

Arc Start/Volt Sense Shutdown

When this feature is on, the system immediately shuts down if no arc voltage is sensed. An error
message is displayed. When this feature is off, wire feeds even when there is no arc voltage sensed.

Wire Feed Mode

Allows the selection of inches per minute or meters per minute for wire feed speed. This mode is also
used to select motor type; standard speed, low speed, or high speed.

4-2.

Lower Front Panel Controls

1

Power Switch

.

The fan motor is thermostatically
controlled and only runs when cooling is
needed.

2

Voltmeter (see Section 4-3)

3

Ammeter (see Section 4-3)

2

3

Ref. 186 067

1

CE

4-3.

Meter Functions

The meters display the actual weld output values for approximately three seconds after the arc
is broken.

Note

Mode

Meter Reading At Idle

Meter Reading While Welding

MIG

Preset Volts

Blank

V

A

24.5

Actual Volts

Actual Amps

V

A

24.5

250

Pulsed

MIG

Pulse Display

Pulse Display

V

A

PPP

PPP

Actual Volts

Actual Amps

V

A

24.5

250