OM-196 188 Page 115

1

Name Display

When a data card is used, the pro-
grams written from the unit to the
card can be named.

Memory
Shutdown

> Name

Program

Card
Programs

> On

Card
Programs

> Off

1

14-14. Selecting Program Name Feature

Press Mode

Select

Increase

Access

Setup

Display

14-15. Remote Program Select

1

Program Display

When Program is On, a remote
device or robot Teach Pendant may
be used to select programs (see
Section 14-16). When Off, program
selection must be done from Setup
Pendant.

Shutdown
Name

> Program

Jog IPM

Remote
Select

> Off

Remote
Select

> On

1

Press Mode

Select

Increase

Access

Setup

Display

14-16. Remote Program Setting

When Remote Program Select is “On”, program selection will be determined by
remote input once a weld is intiated. In “Standby” mode, program selection can be
done in a normal manner from the Setup Pendant.

NOTE

See the following table for the remote program select binary code.

Program No.

Output A

Output B

Output C

1

Off

Off

Off

2

On

Off

Off

3

Off

On

Off

4

On

On

Off

5

Off

Off

On

6

On

Off

On

7

Off

On

On

8

On

On

On