3. setting weld sequence display, 4. setting crater sequence display – Miller Electric Welder User Manual

Page 95

Advertising
background image

OM-196 188 Page 89

9-3.

Setting Weld Sequence Display

1

Weld Parameters Display

Parameter ranges are as follows:

Trim (Arc Length), 0-99

Wire Feed Speed, 50-780 Inches
Per Minute, IPM

Go to Section 9-4.

Weld

60 Trim

> 200 IPM

> Weld

60 Trim
300 IPM

1

Weld

> 50 Trim

200 IPM

Increase/

Decrease

Set Desired Weld

Sequence Trim

Parameter

Select

Set Desired Weld Sequence

Wire Feed Speed

Increase/

Decrease

Parameter

Select

Increase

Proceed to next Section.

9-4.

Setting Crater Sequence Display

1

Crater Parameters Display

Parameter ranges are as follows:

Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.

Trim (Arc Length), 0-99

Wire Feed Speed, 50-780 Inches
Per Minute, IPM

Go to Section 9-5.

1

>Cratr

0.00 Sec
50 Trim
200 IPM

Cratr
0.20 Sec

> 50 Trim

200 IPM

Cratr
0.20 Sec
60 Trim

> 150 IPM

Cratr

> 0.00 Sec

50 Trim
200 IPM

> Cratr

0.20 Sec
60 Trim
150 IPM

Parameter

Select

Set Desired

Time

Parameter

Select

Increase/

Decrease

Increase/

Decrease

Increase/

Decrease

Parameter

Select

Parameter

Select

Increase

Proceed to next Section.

Set Desired Wire

Feed Speed

Set Desired

Trim