OM-196 188 Page 117

1

Monitor Display

Provides a means to enable/dis-
able the arc voltage error feature
and to set an acceptable range of
deviation from set arc voltage or arc
length (trim) before the error will ac-
tuate.

When this feature is off, arc voltage
or arc length variations will not
cause an error or shut the unit
down.

When this feature is on and a range
of deviation is set (the range limits
are

±

0.1 to 9.9 volts from desired

weld voltage, and

±

0.1 to 9.9 sec-

onds), arc voltage or arc length
variations outside of the defined
range, for a period of time exceed-
ing the defined acceptable time pe-
riod, cause either the error relay to
energize or the unit to shut down
depending on the Arc Start/Volt
Sense shutdown error setting.

Jog IPM
Flow

> Monitor

Stick

Arc Volts

> On

2.0 Volts
1.0 Sec

Arc Volts

> Off

1

.

When a system reset is
done, Monitor is set to Off.

14-19. Arc Voltage Error Selection

Press Mode

Select

Increase

Access

Setup

Display

1

Stick Check Display

When stick check is On, a stick
check routine is performed at the
end of each weld. When Off, no
stick check is done.

Flow
Monitor

> Stick

Ramps

Stick
Check

> On

Stick
Check

> Off

1

14-20. Stick Check Selection

Press Mode

Select

Increase

Access

Setup

Display