4 uart mode baud rates, 5 serial interface timing, 1 synchronous serial mode timing – Lucent Technologies MN10285K User Manual

Page 130

Advertising
background image

Serial Interfaces

UART Mode Baud Rates

MN102H75K/F75K/85K/F85K LSI User Manual

Panasonic Semiconductor Development Company

129

Panasonic

5.4

UART Mode Baud Rates

In UART mode, the serial interface transfer clock is set to 16 times the baud rate

clock. The expression below is the formula for calculating the baud rate for the
UART mode. Table 5-2 shows the baud rate settings when B

OSC

= 24 MHz.

5.5

Serial Interface Timing

5.5.1

Synchronous Serial Mode Timing

In these timing charts, the character length is 8 bits and there is parity.

Table 5-2 Example Baud Rate Settings for the UART Mode

Baud Rate

Timer 0/1 Divide-by Ratio

19200

9600

4800

2400

1200

600

300

39

78

156

313

625

1250

2500

Figure 5-5 Synchronous Serial Transmission Timing

baud rate (bps)

B

OSC

32

(timer divisor)

×

-----------------------------------------------

=

SBO

SBT

Data write

TXBUSY

Tx interrupt

b0 b1 b2 b3 b4 b5 b6 b7 PTY

Tx

Advertising