Serial Interfaces

Serial Interface Setup Examples

MN102H75K/F75K/85K/F85K LSI User Manual

Panasonic Semiconductor Development Company

131

Panasonic

5.6

Serial Interface Setup Examples

5.6.1

Setting Up UART Transmission Using Serial Interface 0

You must use an 8-bit timer to

set the transfer clock. See sec-
tion 5.6.3, “Setting Up the Serial

Interface Clock,” on page 135,

for an example setup.

This example illustrates serial transmission in the UART mode with the fol-

lowing settings:

B

OSC

= 24 MHz

Baud rate = 9600 bps (transfer clock set up with timer 0)

8-bit character length

Two stop bits

Odd parity

When a transmission end interrupt occurs, the next data byte is loaded.

Data transmission starts when the CPU writes data to the SC0TRB register. The
transmission start is synchronized to timer 0 underflow. An interrupt occurs when

transmission ends, and the next data byte is written to SC0TRB. If the application
does not use interrupts, it must poll the SC0TBY flag of the SC0STR register. It

can write the transmission data when SC0TBY is 0.

To set up the output port:

Set the P5MD5 bit of the port 5 output mode register (P5MD) to 1. This selects

the SBO0 pin as the serial interface output port.

P5MD (example)

x’00FFFA’

Figure 5-9 Block Diagram of UART Transmission Using Serial Interface 0

SBO0

P0

P2

P4

P6

CORE

Interrupts

Timers 0-1

Timers 2-3

ROM, RAM

Bus Controller

Serial I/Fs

ADC

P1

P3

P5

Bit:

7

6

5

4

3

2

1

0

P5

MD7

P5

MD6

P5

MD5

P5

MD4

P5

MD3

P5

MD2

P5

MD1

P5

MD0

Setting:

0

1

0

0

0

0

0

0