H Counter

H Counter Control Registers

Panasonic Semiconductor Development Company

MN102H75K/F75K/85K/F85K LSI User Manual

310

Panasonic

14.4 H Counter Control Registers

All registers in H Counter block cannot be written by byte (by word only). Read

by byte is possible.

HCCNT0: H Counter Control Register 0

x’007EB0’

SEDG0: Polarity select for count source signal (HI0)

0: Active low

1: Active high

SEDG0: Polarity select for reset signal

0: Active low
1: Active high

SELR20:00]: Reset signal select

000: 1024 µs
001: 2048 µs

010: 4096 µs
011: 8192 µs

100: VI0
101: VSYNC

All other settings default to 1024 µs.

HCCNT1: H Counter Control Register 1

x’007EB2’

SEDG1: Polarity select for count source signal (HI1)

0: Active low
1: Active high

SEDG1: Polarity select for reset signal

0: Active low

1: Active high

SELR[21:01]: Reset signal select

000: 1024 µs

001: 2048 µs
010: 4096 µs

011: 8192 µs
100: VI0

101: VSYNC

All other settings default to 1024 µs.

Bit:

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

SED

G0

RED

G0

SELR

20

SELR

10

SELR

00

Reset:

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

R/W:

R

R

R

R

R

R

R

R

R

R

R

R/W

R/W

R/W

R/W

R/W

Bit:

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

SED

G1

RED

G1

SELR

21

SELR

11

SELR

01

Reset:

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

R/W:

R

R

R

R

R

R

R

R

R

R

R

R/W

R/W

R/W

R/W

R/W