Output Solutions 650 User Manual

Page 168

Advertising
background image

C-24

ESC b n m1 mk NUL

Set Vertical Tab in Tab Set n

Sets vertical tab stops at the lines specified by m1 to mk (in the current line spacing) in tab set n
as measured from the top-of-form position. The tab stops must be in ascending order.

A maximum of 16 vertical tab stops can be set in each tab set

Hex:

(1B 61 n m1 … mk 00)H

Decimal:

(27 97 n m1 … mk 00)D

Octal:

(33 141 n m1 … mk 00)O



HT

Horizontal Tabulation

This command moves the horizontal position to the right to the next horizontal tab stop.
If there is no tab stop between the current position and the right margin, this command will be
ignored or executed as a CR + LF according to menu setup.

Hex: (09)H
Decimal: (09)D
Octal: (11)O


VT

Vertical Tabulation

This command causes the current position to move down to the next vertical tab stop.
If there is no tab stop beyond the current position, the printer executes this command
as CR + LF.

Hex: (0B)H
Decimal: (11)D
Octal: (13)O

Advertising