Chapter 11: Differential Equation Graphing 195

11DIFFEQ.DOC TI-89/TI-92 Plus: Differential Equation (English) Susan Gullord Revised: 02/23/01 11:04 AM Printed: 02/23/01 2:15 PM Page 195 of 26

16. In the Window Editor, set

the Window variables.

xmin=

ë

10.

ymin=

ë

10.

xres=2.

xmax=100.

ymax=120.

xscl=10.

yscl=10.

17. Display the Graph screen

(

¥ % ).

18. In the Window Editor, set the

Window variables to zoom in
so that you can examine the
differences in more detail.

xmin=39.7

ymin=85.5

xres=2.

xmax=40.3

ymax=86.

xscl=.1

yscl=.1

19. Return to the Graph screen.

20. Press … to trace, and then

press C or D until

y1

is

selected. (

1

shows in upper

right corner.) Then enter 40.

By moving the trace cursor to trace each solution to

xc = 40

, you can

find that:

¦

The exact solution (

y1

) is 85.8486, rounded to six digits.

¦

The

RK

solution (

Plot 1

) is 85.8952.

¦

The

Euler

solution (

Plot 2

) is 85.6527.

You can also use the Data/Matrix Editor to open the

errorlog

data

variable and scroll to

time = 40

.

Note: The fuzzy line on the
graph indicates differences
between the RK and Euler
values.

y1 is selected when 1 shows here.