224 Chapter 13: Tables

13TABLES.DOC TI-89/TI-92 Plus: Tables (English) Susan Gullord Revised: 02/23/01 1:08 PM Printed: 02/23/01 2:16 PM Page 224 of 10

To display the

TABLE SETUP

dialog box, press ¥ &. From the

Table screen, you can also press „.

Setup Parameter

Description

tblStart

If

Independent = AUTO

and

Graph <

-

> Table

=

OFF

,

this specifies the starting value for the independent
variable.

@

tbl

If

Independent = AUTO

and

Graph <

-

> Table

=

OFF

,

this specifies the incremental value for the
independent variable.

@

tbl

can be positive or

negative, but not zero.

Graph <

-

> Table

If

Independent

=

AUTO

:

OFF

— The table is based on the values you enter

for

tblStart

and

@

tbl

.

ON

— The table is based on the same independent

variable values that are used to graph the functions
on the Graph screen. These values depend on the
Window variables set in the Window Editor
(Chapter 6) and the split screen size (Chapter 14).

Independent

AUTO

— The

TI

-89 / TI-92 Plus

automatically

generates a series of values for the independent
variable based on

tblStart

,

@

tbl

, and

Graph <

-

> Table

.

ASK

— Lets you build a table manually by entering

specific values for the independent variable.

Setting Up the Table Parameters

To set up the initial parameters for a table, use the

TABLE

SETUP

dialog box. After the table is displayed, you can also

use this dialog box to change the parameters.

Displaying the

TABLE SETUP

Dialog Box

Note: The table initially
starts at tblStart, but you
can use

C

to scroll to prior

values.