Electrostatic discharges, and earth currents, Ambient light – Zebra Technologies TTP 8000 User Manual

Page 17

Advertising
background image

17

Installation

Installation Considerations

10/19/2009

TTP 8000 Technical Manual

P1003638-003

Electrostatic Discharges, and Earth Currents

Preventing ESD and earth currents from affecting the printer operation requires proper
connection of the printer chassis to protective earth through a mounting platform or through a
separate earth conductor. The signal ground is not connected to protective earth (chassis)
inside the printer.

See

Figure 6

. Fasten an earth cable to the printer using an M4x6 screw. Always put a lock

washer between the chassis and the connector.

Figure 6 • Attach Earth Cable

Ambient Light

There are optical sensors just inside the paper exit at the front of the printer.

To ensure proper printer operation, design the printer enclosure so that it prevents direct
sunlight or light from indoor lamps from reaching the sensor through the paper exit.

Advertising