Serial interface set-up – Zebra Technologies TTP 8000 User Manual

Page 74

Advertising
background image

Default Parameter Settings
Serial Interface Set-up

74

P1003638-003

TTP 8000 Technical Manual

10/19/2009

Serial Interface Set-up

Stores the communication speed on the serial interface.

Selects if 7-bit ASCII, or 8-bit, is used on the serial interface.

<

Select what parity to use on the serial interface.

1

96 Default

Baud Rate

24 Min
11 Max

<ESC>&P<1><24>

2400 bps

<ESC>&P<1><48>

4800 bps

<ESC>&P<1><96>

9600 bps

<ESC>&P<1><19>

19200 bps

<ESC>&P<1><38>

38400 bps

<ESC>&P<1><57>

57600 bps

<ESC>&P<1><11>

115200 bps

Note •

If you set an invalid value, the baud rate will return to the previous value.

2

8 Default

Data Bits

7 Min
8 Max

<ESC>&P<2><8>

8-bits (characters 0-255)

<ESC>&P<2><7>

7-bits (characters 0-127)

Note •

In 7-bit mode you can not print graphic, read status or set parameters because no

value can ever be greater than 127.

3

0 Default

Parity

0 Min
2 Max

<ESC>&P<3><0>

No parity

<ESC>&P<3><1>

Odd parity

<ESC>&P<3><2>

Even parity

Advertising