Default Parameter Settings
Fixed Document Mode

86

P1003638-003

TTP 8000 Technical Manual

10/19/2009

You can lock the parameters so that they cannot be changed by the ESC & P command.

Adds a delay between the burning of blocks in the printhead. This delay helps possible for the
power supply to recover from the heavy load of heating pixels. If you have a somewhat weak
power supply, print quality can be enhanced by increasing this value. A high value slows the
printout down slightly.

Recommended settings: 0 for 300 W (12.5 A) PSU, 255 for 150 W (6.5 A PSU)

53

0 Default

Lock Parameters

0 Min
1 Max

<ESC>&P<53><0>

Unlocked

<ESC>&P<53><1>

Locked

55

255 Default

PSU Recovery

0 Min

255 Max