Connecting the power – Zebra Technologies TTP 8000 User Manual

Page 20

Advertising
background image

Installation
Connecting to the Computer

20

P1003638-003

TTP 8000 Technical Manual

10/19/2009

Connecting the Power

1.

Attach a ground cable to the ground screw on the printer.

2.

Connect the cable from the power supply to J8.

3.

Connect the power cable to the line outlet.

4.

Apply power to the printer.

If you use another type of power supply unit, connect the voltages according to the following
illustration.

At the printer end of the cable, use a Tyco Mate-N-Lok connector housing and two
contact-sockets:

Figure 9 • Power Connection

Caution •

Use only the recommended Zebra power supply (see

Part Number List

on page 124

for part number).

Important •

The ground and the 24 V ground must be separated in the power supply to avoid

ground loops!

Tyco No. 350777-1

Tyco No. 350689-1

Table 5 • Current Consumption at Factory Default Settings

Print Density

TTP 8200

TTP 8300

None (Idle)

0.15 A

0.15 A

10% coverage

1 A

2 A

20% coverage

2 A

3 A

30% coverage

3 A

4 A

40% coverage

4 A

5 A

50% coverage

5 A

6 A

All black printing

10 A

12 A

Note •

Print speed, burn time, and temperature affects these values.