Zebra Technologies TTP 8000 User Manual

Page 75

Advertising
background image

75

Default Parameter Settings

Serial Interface Set-up

10/19/2009

TTP 8000 Technical Manual

P1003638-003

Select what handshaking to use on the serial interface.

4

2 Default

Flow-control

0 Min
2 Max

<ESC>&P<4><0>

No flow control

<ESC>&P<4><1>

Xon / Xoff *

*. DO NOT USE if you send any type of binary data like graphics data, status requests etc.
Xon / Xoff only works when plain text is sent unidirectional to the printer. Graphics and
status replies may well contain the Xon (11 hex) and Xoff (13 hex) characters and will ob-
struct the communication.

<ESC>&P<4><2>

Hardware

Advertising