TT Command - Define Time Layout

Description Use this command to define the time format

when printing.

Syntax

TTp

1

[|p

2

|p

3

][+]

Parameters

P

1

,

P

2

,

P

3

=

h, m,

or

s

These parameters describe the format of

the time display.

·

At lease one parameter must be supplied.

·

Each parameter can be any of the values

h

,

m

, or

s

and are described below.

Value

Description

h

Hours displayed as 2 digits (e.g. 01)

m

Minutes displayed as 2 digits (e.g. 15)

s

Seconds displayed as 2 digits (e.g. 00)

[+]

=

Enable 12 Hour clock format

Appending a + to the end of the com-

mand string selects 12 hour clock mode.

The times will display with an “AM” or

“PM” indicator.

Default

(no

+

) =

24

hour clock mode

|

= Separator character

The separator may be any ASCII char-

acter value between 032 and 063. The

separator character is printed between

the results of each of the supplied pa-

rameters.

This command works only in printers equipped with

the Real Time Clock time and date option.

Examples: If the current time is 1:25 p.m.:

TTh:m:s+↵

: 01:25:00

TTh,m↵

: 13,25

TTh+↵

: 01 PM

980352-001 Rev.A

3-89