p

Command - Generate Pulse CDK

Description Generate a drawer kicker pulse.

Syntax

<Esc>pp

1

p

2

p

3

Parameters

p

1

= Select Drawer

Drawer 1 (SDRV1) = 31 hex.

Drawer 2 (SDRV2) = 32 hex.

p

2

= Pulse “on” time in multiples of two milli-

seconds (2 msec).

Range = 00 - FF hex.

p

3

= Pulse “on” time in multiples of two milli-

seconds (2 msec). The value of

p

3

must

be greater than or equal to the value of

p

2

.

ASCII Hex Value 1B 70

p

1

p

2

p

3

(

p

1

represent value range 31 to 32 hex;

p

2

represent value range 00 to FF hex;

p

3

represent value range 00 to FF hex)

Example

←p2Bd↵

: ←p = <Esc>p , the command

: 2 = p1 parameter value of 32 hex.

: B = p2 parameter value of 42 hex. for

:

132 msec pulse (66 x 2msec)

: d = p3 parameter value od 64 hex. for

:

200 msec. pulse (100 x 2msec)