Y - serial port setup 3-108, Command - serial port setup -108, Y command - serial port setup – Zebra Technologies EPL2 User Manual

Page 126

Advertising
background image

Y Command - Serial Port Setup

Description Use this command to establish the serial port

communication parameters.

Syntax

Yp

1

,

p

2

,

p

3

,

p

4

Parameters

p

1

= Baud rate

p1

Description

38

38,400 baud (38K)

19

19,200 baud

96

9,600 baud

48

4,800 baud

24

2,400 baud

12

1,200 baud

p

2

= Parity.

Values:

O

= Odd parity

E

= Even parity

N

= No parity

p

3

= # Data bits.

Values:

7

= Seven data bits

8

= Eight data bits

p

4

= # Stop bits.

Values:

1

= One stop bit

2

= Two stop bits.

After receiving this command, the printer will

automatically reset enabling the new rate.

To send commands and data to the printer, the host’s

serial port parameters must match the printer’s serial

port parameters. Verify the printer’s configuration set-

tings with the AutoSense/Dump Mode Printout, see

the printer’s user’s manual for details.

The printer’s default serial port parameters are:

9600 baud, No Parity, 8 Data Bits, 1 Stop Bit

Change the printer’s serial port parameters with the

Y

command after communication has been estab-

lished with the host. The host parameters must then

be changed to resume communication.

Example:

Y19,O,7,1

¿

:sets 19,200 baud, odd parity,

:7 data bits and 1 stop bit.

3-108

980352-001 Rev.A

Advertising