B command - 2d bar code - pdf417 specific options – Zebra Technologies EPL2 User Manual

Page 39

Advertising
background image

b Command - 2D Bar Code - PDF417 Specific Options

The following parameters may be omitted and de-

fault values will automatically be inserted. Each pa-

rameter value (data string) must be proceeded by its

associated command prefix character.

p

6

(s)

= sets error correction level

Error Correction codewords per symbol

Values:

s1

-

s8

If level is not specified, a level will automati-

cally be assigned as per the following table:

EC level EC Codewords

Auto Select Level

0

2

1

4

0-31

2

8

32-63

3

16

64-127

4

32

128-255

5

64

256-511

6

128

512-928

7

256

8

512

p

7

(c)

= selects data compression method

Values:

0

or

1

, default is

0

c0

= Auto-encoding

c1

= Binary mode

Data Type Compression (Byte by Byte)

Text

2 Characters per codeword

Numeric

2.93 Characters per codeword

Binary

1.2 Bytes per codeword

p

8

(pxxx,yyy,mm)

= print human readable

This parameter is a non-standard implemen-

tor of the PDF417 and is only

recommended for troubleshooting purposes.

Additional variables:

p

="

p

" - parameter identifier

xxx

= horizontal start location

yyy

= vertical start location

mm

= maximum characters per line

980352-001 Rev.A

3-21

Advertising