oW Command - Customize Bar Code Parameters

Description: This command allows the advanced program-

mer to modify specific bar code parameters to

exceed the specified bar code’s design toler-

ances, i.e. reduce the bar code size.

Using the

oW

command may cause bar codes to be-

come unreadable by some or all bar code scanners.

Syntax:

oWp

1

,

p

2

,

p

3

,

p

4

,

p

5

Parameters:

p

1

= Initial width narrow white bar.

Default value is 2

p

2

= Initial width narrow black bar.

Default value is 2

p

3

= Initial width wide white bar.

Default value is 4

p

4

= Initial width wide black bar.

Default value is 4

p

5

= Initial bar code gap.

Default value is 3

The

oW

command is a global printer command.

❏They can not be issued inside of a form.
❏They must be issued prior to issuing a bar

code command (and printing).

❏Use only one bar code format. Using more

than one bar code may cause unpredictable

results or operation.

❏Issue all 5 command parameters (p1-5 ). Use

the default parameter values as place holders.

❏Bar code printed with this command should

be printed in the picket fence orientation (0º

& 180º rotations) to maximize scanning.

980352-001 Rev.A